Wait a second...
Nepřihlášený uživatel
You are here: UCT PragueÚAPV → Research → Instrumentation → GC/MS
iduzel: 21920
idvazba: 27247
šablona: stranka_galerie
čas: 29.3.2024 01:24:18
verze: 5378
uzivatel:
remoteAPIs:
branch: trunk
Server: 147.33.89.150
Obnovit | RAW
iduzel: 21920
idvazba: 27247
---Nová url--- (newurl_...)
domena: 'uapv.vscht.cz'
jazyk: 'en'
url: '/research/equipment/21920'
iduzel: 21920
path: 8548/15102/15104/15108/15220/21914/21920
CMS: Odkaz na newurlCMS
branch: trunk
Obnovit | RAW

GC/MS

GC-MSMS Agilent 7000B Triple QuadrupoleA (originál)GC-MS/MS Agilent 7000B Triple Quadrupole

Gas chromatography coupled to tandem mass spectrometry (triple quadrupole) equipped with electron impact ionization technique is employed for the analysis of pesticide residues in a wide range of foodstuffs (e.g. fruit, vegetable, tea, cereals). This instrumentation allows to measure more than 300 pesticide residues in less than 30 minutes at ultra-trace concentrations in one run. This system is also equipped with a JetClean function for self-cleaning ion source with hydrogen.

Publications

Drabova L., Alvarez-Rivera G., Suchanova M., Schusterova D., Pulkrabova J., Tomaniova M., Kocourek V., Chevallier O., Elliot Ch., Hajslova J.: Food fraud in oregano: pesticide residues as adulteration markers. Food Chemistry (2019) 276:726-734. (doi:10.1016/j.foodchem.2018.09.143)

Cajka T., Sandy C., Bachanova V., Drabova L., Kalachova K., Pulkrabova J., Hajslova J.: Streamlining sample preparation and gas chromatography-tandem mass spectrometry analysis of multiple pesticide residues in tea. Anal. Chim. Acta (2012) 743:51–60. (doi: 10.1016/j.aca.2012.06.051)

 

GC-MSMS Agilent 7000B Triple Quadrupole (originál)GC-MS/MS Agilent 7000B Triple Quadrupole

Gas chromatography coupled to tandem mass spectrometry (triple quadrupole) is particularly used for the analysis of environmental contaminants (e.g. polychlorinated biphenyls, flame retardants, organochlorine pesticides). Applications allow multi-detection analysis in a wide range of environmental (e.g. soil or atmosphere), food (e.g. meat, fat, fruit or vegetable) and biological (e.g. human breast milk or human blood serum) samples. This second triplequad system is also possible to operate in chemical ionization suitable particularly for the analysis of halogenated compounds and it is equipped with fully automated device for solid phase microextraction (CTC Pal) for the analysis of volatile compounds.

Publications

Polachova A., Gramblicka T., Parizek O., Sram R.J., Stupak M., Hajslova J., Pulkrabova J.: Estimation of human exposure to polycyclic aromatic hydrocarbons (PAHs) based on the dietary and outdoor atmospheric monitoring in the Czech Republic. Environmental Research (2020) 182: 108977. (doi: 10.1016/j.envres.2019.108977)

Logerova H., Tuma P., Stupak M., Pulkrabova J., Dlouhy P.: Evaluation of the burdening on the Czech population by brominated flame retardants. International Journal of Environmental Research and Public Health (2019) 16(21) 4105. (doi: 10.3390/ijerph16214105 )

Pulkrabova J., Cerny J., Szakova J., Svarcova A., Gramblicka T., Hajslova J., Balik J., Tlustos P.: Is the long-term application of sewage sludge turning soil into a sink for organic pollutants?: evidence from field studies in the Czech Republic. Journal of Soils and Sediments (2019) 19: 2445-2458. (doi:10.1007/s11368-019-02265-y)

Svarcova A., Lankova D., Gramblicka T., Stupak M., Hajslova J., Pulkrabova J.: Integration of five groups of POPs into one multi-analyte method for human blood serum analysis: An innovative approach within biomonitoring studies. Science of The Total Environment (2019) 667: 701-709. (doi: 10.1016/j.scitotenv.2019.02.336)

Szakova J., Pulkrabova J., Cerny J., Mercl F., Svarcova A., Gramblicka T., Najmanova J., Tlustos P., Balik J.: Selected persistent organic pollutants (POPs) in the rhizosphere of sewage sludge-treated soil: Implications for the biodegradability of POPs. Archives of Agronomy and Soil Science (2019) 65(7): 994-1009. (doi:10.1080/03650340.2018.1543945)

Pulkrabova J., Stupak M., Svarcova A., Rossner P., Rossnerova A., Ambroz A., Sram R., Hajslova J.: Relationship between atmospheric pollution in the residential area and concentrations of polycyclic aromatic hydrocarbons (PAHs) in human breast milk. Science of the Total Environment (2016) 562: 640-647. (doi: 10.1016/j.scitotenv.2016.04.013)

Kalachova K., Cajka T., Sandy C., Hajslova J., Pulkrabova J.: High throughput sample preparation in combination with gas chromatography coupled to triple quadrupole tandem mass spectrometry (GC-MS/MS): a smart procedure for (ultra)trace analysis of brominated flame retardants in fish. Talanta (2013) 105:109–116.(doi: 10.1016/j.talanta.2012.11.073)

Kalachova K., Pulkrabova J., Cajka T., Drabova L., Stupak M., Hajslova J.: Gas chromatography–triple quadrupole tandem mass spectrometry: A powerful tool for the (ultra)trace analysis of multi-class environmental contaminants in fish and fish feed. Anal. Bioanal. Chem., (2013) 405: 7803–7815 (doi: 10.1007/s00216-013-7000-4)

 

GC-MSMS Agilent 7000C Triple Quadrupole (originál)GC-MS/MS Agilent 7000C Triple Quadrupole

Gas chromatography coupled to tandem mass spectrometry (triple quadrupole) is an alternative technique to a system Agilent 7000B for the analysis of environmental contaminants (e.g. polychlorinated biphenyls, flame retardants, organochlorine pesticides). Applications allow multi-detection analysis in a wide range of environmental (e.g. soil or atmosphere), food (e.g. meat, fat, fruit or vegetable) and biological (e.g. human breast milk or human blood serum) samples. By Agilent 7000C system we can achieved lower limits of quantification for target analytes compared to the system Agilent 7000B. This system is also equipped with a JetClean function for self-cleaning ion source with hydrogen.

 

GC-MSMS Agilent 7010 Triple Quadrupole (originál)GC-MS/MS Agilent 7010 Triple Quadrupole

The last generation of gas chromatography coupled to tandem mass spectrometry (triple quadrupole) is employed for the analysis of pesticide residues in a wide range of foodstuffs (e.g. fruit, vegetable, tea, cereals) and environmental samples. This instrument allows to measure more than 300 pesticide pesticides in less than 30 minutes in one run. Its high-efficiency electron impact ion source produces at least 20 times as many ions as the previous generation, improving the efficiency of the entire workflow.

  

   

GC-HRMS Pegasus HRT (LECO) (originál)GC-HRMS Pegasus HRT (LECO)

Gas chromatography coupled to high resolution mass spectrometry (time of flight analyzer) enable resolution of 50,000 FWHM and mass accuracies less than 1 ppm is used for target and non-target analysis of volatile and semi-volatile compounds. This technique is equipped with a fully automated device for solid phase microextraction (Gerstel). GC-HRMS Pegasus HRT is employed for non-target analysis of volatiles in variable samples, for a routine analysis of furans or dithiocarbamates and for a practical training of students.

Publications

Gracka A., Raczyk M., Hradecky J., Hajslova J., Jeziorski S., Karlovits G., Michalak B., Bąk N. and Jeleń H.: Volatile compounds and other indicators of quality for cold-pressed rapeseed oils obtained from peeled, whole, flaked, and roasted seeds. European Journal of Lipid Science Technology (2017) 119 (10). (doi:10.1002/ejlt.201600328)

Hradecky J., Kludska E., Belkova B., Wagner M., Hajslova, J.: Ohmic heating: A promising technology to reduce furan formation in sterilized vegetable and vegetable/meat baby foods. Innovative Food Science and Emerging Technologies (2017) 43: 1-6. (doi: 10.1016/j.ifset.2017.07.018)

 

GC-MS Agilent 5973 Single Quadrupole  (originál)GC-MS Agilent 5973 Single Quadrupole

Gas chromatography coupled to mass spectrometry (single quadrupole) is particularly used in student laboratory courses. In the courses, students learn detail functions of this instrumentation and try some GC-MS application (e.g. the determination of volatile compounds in spices or the alcoholic beverages quality determination).

Publications

Stupak M, Kocourek V., Kolouchova I., Hajslova J.: Rapid approach for the determination of alcoholic strength and overall quality check of various spirit drinks and wines using GC–MS. Food Control (2017) 80: 307-313 (doi: 10.1016/j.foodcont.2017.05.008)

 

GCxGC-MS Pegasus® 4D (originál)GCxGC-MS Pegasus® 4D

Gas chromatography enabling two dimensional separation coupled to mass spectrometry (time of flight analyzer) is particularly used for the determination of volatile and semi-volatiles compounds in extremely complex matrixes (e.g. mineral oils). This technique has fully automated device for solid phase microextraction (Gerstel). Other applications employing GCxGC-MS Pegasus® 4D are the analysis of environmental contaminants (e.g. polychlorinated biphenyls, flame retardants or organochlorine pesticides) and terpenoic compounds in cannabis and cannabis products.

Publications

Gracka A., Raczyk M., Hradecky J., Hajslova J., Jeziorski S., Karlovits G., Michalak B., Bąk N. and Jeleń H.: Volatile compounds and other indicators of quality for cold-pressed rapeseed oils obtained from peeled, whole, flaked, and roasted seeds. European Journal of Lipid Science Technology (2017) 119 (10) . (doi:10.1002/ejlt.201600328)

Drabova L., Pulkrabova J., Kalachova K., Tomaniova M., Kocourek V., Hajslova J.: Polycyclic aromatic hydrocarbons (PAHs) and halogenated persistent organic pollutants (POPs) in canned fish and seafood products: smoked versus non-smoked products. Food Addit. Contam. A (2013) 30:5152–527. (doi: 10.1080/19440049.2012.755645)

Drabova L., Tomaniova M., Kalachova K., Kocourek V., Hajslova J., Pulkrabova J.: Application of solid phase extraction and two-dimensional gas chromatography coupled with time-of-flight mass spectrometry for fast analysis of polycyclic aromatic hydrocarbons in vegetable oils. Food Control (2013) 33: 489–497. (doi: 10.1016/j.foodcont.2013.03.018)

Drabova L., Pulkrabova J., Kalachova K., Tomaniova M., Kocourek V., Hajslova J.: Rapid determination of polycyclic aromatic hydrocarbons (PAHs) in tea using Two-Dimensional Gas Chromatography coupled with Time of Flight Mass Spectrometry. Talanta (2012) 100:207–216. (doi:10.1016/j.talanta.2012.07.081)

Kalachova K., Pulkrabova J., Cajka T., Drabova L., Hajslova J.: Implementation of comprehensive two-dimensional gas chromatography–time-of-flight mass spectrometry for the simultaneous determination of halogenated contaminants and polycyclic aromatic hydrocarbons in fish. Anal. Bioanal. Chem. (2012) 403:2813–2824. (doi: 10.1007/s00216-012-6095-3)

Drábová L., Pulkrabová J., Kalachová K., Hradecký J., Suchanová M., Tomaniová M., Kocourek V., Hajšlová J.: Novel approaches to determination of PAHs and halogenated POPs in canned fish. Czech J. Food Sci. (2011) 29:498–507

Kalachova K., Pulkrabova J., Drabova L., Cajka T., Kocourek V., Hajslova J.: Simplified and rapid determination of polychlorinated biphenyls, polybrominated diphenyl ethers, and polycyclic aromatic hydrocarbons in fish and shrimps integrated into a single method. Anal. Chim. Acta (2011) 707:84–91. (doi: 10.1016/j.aca.2011.09.016)

 

  

GC-HRMS Agilent 7200b (originál)GC-HRMS Agilent 7200b

Agilent 7200b is a system consists of gas chromatography and high resolution tandem mass spectrometry (quadrupole-time of flight analyzer). This instrumentation is mostly applied for non-target analysis (e.g. determination of Scotch whisky authenticity) as well as for target analysis (e.g. chlorinated paraffins in foodstuffs and biological samples, pesticide residues in foodstuffs, terpenoic compounds in cannabis and cannabis products and determination of spirits quality). This instrument is also equipped with fully automated device for solid phase microextraction and chemical (positive/negative) ionization. Agilent 7200b is also used in student laboratory courses.

Publications

Stupak M., Goodall I., Tomaniova M., Pulkrabova J., Hajslova J.: A novel approach to assess the quality and authenticity of Scotch Whisky based on gas chromatography coupled to high resolution mass spectrometry. Analytica Chimica Acta (2018) 1042:60-70. (doi: 10.1016/j.aca.2018.09.017)

Stupak M, Kocourek V., Kolouchova I., Hajslova J.: Rapid approach for the determination of alcoholic strength and overall quality check of various spirit drinks and wines using GC–MS. Food Control (2017) 80: 307-313 (doi: 10.1016/j.foodcont.2017.05.008)


Updated: 11.5.2021 13:54, Author: Martina Vlčková

UCT Prague
Technická 5
166 28 Prague 6 – Dejvice
IČO: 60461373 / VAT: CZ60461373

Czech Post certified digital mail code: sp4j9ch

Copyright: UCT Prague 2015
Information provided by the Department of International Relations and the Department of R&D. Technical support by the Computing Centre.
switch to mobile version